As AI demand continues to push data center server racks to higher power ratings, air cooling has reached its limit. Direct-to-chip liquid cooling has become the default cooling architecture for top AI server racks such as NVIDIA's Vera Rubin architecture, forcing operators to quickly adopt the technology. As server racks continue to push to higher power ratings, perhaps exceeding 1MW through the next decade, emerging liquid cooling strategies, including immersion cooling and two-phase technologies, may quickly become necessary to keep up with evolving chip and rack architectures.
AI's bottlenecks are multiplying. As models become increasingly complex and require greater computational power, the challenge of AI training is shifting away from a localized problem ("how good is my chip?") to a much larger, system-wide challenge, encompassing power generation and distribution, connectivity, and cooling. With racks pushing from tens to hundreds and perhaps even thousands of kW by the next decade, getting power in and getting heat out become both more difficult and more critical. While traditional air cooling will remain sufficient for many low-power, non-AI applications, air has essentially reached its thermal limit for the most powerful racks. Direct liquid cooling has become the default for high-power servers, rather than just an efficiency-boosting addition. IDTechEx's latest report, "Liquid Cooling for Data Centers 2027-2037: Technologies, Markets, and Opportunities", whichforecasts the direct-to-chip cooling and immersion cooling markets to together exceed US$28 billion by 2037, evaluates single-phase and two-phase cooling technologies, for both direct-to-chip and immersion cooling. It benchmarks over 100 different cooling fluids, and details IDTechEx's predicted roadmap for data center liquid cooling, based on independent market analysis and primary research from leading players across the data center industry.

Comparison of single-phase direct-to-chip, two-phase direct-to-chip, single-phase immersion, and two-phase immersion cooling
Single-phase direct-to-chip shifts from optional to essential for high-power server racks
Prior to the release of ChatGPT at the end of 2022, it was unusual for server racks to operate above 20-30kW, a power range for which air cooling is sufficient. Liquid cooling (typically single-phase direct-to-chip cooling, which utilizes a cold plate and PG25 coolant) was an option, but efficiency gains were offset by increased CAPEX and system complexity which compounded over the scale of a full data center. However, increased rack power, driven by increased chip thermal design power (TDP), has pushed air cooling to its limit. It is not only the case that direct-to-chip liquid cooling offers efficiency gains over air cooling, but the greater thermal conductivity of PG25 over air allows the cooling of more powerful server racks. NVIDIA's latest Vera Rubin server racks are 100% liquid cooled by default, without air-cooling optionality. The servers are simply too powerful to be cooled by air. For data center operators, flexibility becomes a key separating factor. Players need to be able to deploy air- and liquid-cooled racks in the same venue, increasing operational complexity.
Over the next decade, cooling architectures are likely to change again, and data center operators need to be ready to implement alternative cooling technologies as soon as the chips demand it. IDTechEx's "Liquid Cooling for Data Centers 2027-2037: Technologies, Markets, and Opportunities" evaluates the cooling architectures beyond single-phase direct-to-chip, providing data center operators clarity on how to prepare for future cooling generations.
Is the industry opinion of immersion cooling off?
Single-phase immersion cooling involves the full submersion of servers in a cooling fluid. In Liquid Cooling for Data Centers 2027-2037, IDTechEx benchmarks a number of different immersion cooling fluid chemistries, including mineral oils, polyalphaolefins (PAOs), esters, silicone oils, and fluorochemicals. The coolant requirements for immersion cooling are fundamentally different to direct-to-chip. As the full server is submerged, material compatibility requirements are much broader, including a wide range of plastics, elastomers, metals, and all other materials comprising a server. The cooling fluid must be a strong dielectric to prevent electrical faults, and the use of organic cooling fluids introduces a flammability risk which must be tightly controlled.
Only a few years ago, there was considerable hype around immersion cooling, touted for its superior cooling efficiency and increased thermal density. However, single-phase direct-to-chip cooling has proved more capable than previously thought as cold plate design has improved, and concerns have arisen over the weight of immersion racks and the feasibility of retrofitting in raised-floor data centers with weight limits. IDTechEx has attended numerous data center conferences over the past years and has observed a recent decline in the number of immersion demonstrations, with two-phase cooling instead taking center stage.
Two-phase offers step-change in power density, step-change in complexity, and step-change in regulatory challenge
Two-phase cooling solutions are possible for both direct-to-chip and immersion, with direct-to-chip increasingly positioned as the successor to single-phase direct-to-chip once its thermal limit is reached. For two-phase cooling, the cooling fluid boils upon contact with the cold plate, removing chip heat through latent heat of vaporization. This method of heat removal is far more efficient than single-phase direct-to-chip, increasing efficiency and, crucially, enabling more powerful server racks. However, managing two phases of cooling fluid, liquid and vapor, increases design complexity across the whole thermal management stack: cold plates, manifolds, coolant distribution units, etc. That said, the overall architecture remains broadly similar to single-phase direct-to-chip, with operators more optimistic about fitting two-phase direct-to-chip cooling solutions.
However, the challenge extends beyond operation to regulation. To meet flammability requirements, two-phase cooling fluids are invariably fluorochemicals and are considered poly- and per-fluoroalkyl substances (PFAS). These chemicals have been used extensively across a wide range of applications but are facing heightened scrutiny around their environmental persistence and adverse health effects. PFAS are expected to face a widespread ban in the EU after a derogation period, casting doubt over the use of these cooling fluids and, indeed, two-phase cooling as a whole in the EU. While such bans are less likely to be adopted in the United States, at least at the federal level, PFAS have been at the center of several high-profile lawsuits in recent years. Data center operators may be hesitant to deploy two-phase cooling systems, fearing similar litigation.
Despite all the challenges around immersion and two-phase cooling fluids, the cooling market is so dictated by the most powerful chips that operators may not have much of a choice. The deployment of single-phase direct-to-chip was essentially mandated by increased rack power; if servers continue in a similar trajectory, IDTechEx expects a similar mandated transition to emerging cooling architectures. These transitions are expected to be sharp, and players across the data center industry need to anticipate these changes and be ready to adapt quickly. IDTechEx's latest report, "Liquid Cooling for Data Centers 2027-2037: Technologies, Markets, and Opportunities" offers benchmarking across incumbent and emerging liquid cooling technologies and coolant chemistries, unpacks the key drivers and regulatory challenges, and provides expert outlook on the cooling technologies of tomorrow that players need to understand today.
For more information on this report, including downloadable sample pages, please visit www.IDTechEx.com/LiquidCooling, or for the full portfolio of related research available from IDTechEx, see www.IDTechEx.com.